A non-loadbearing partition of lipped steel studs staggered between the two plasterboard faces in floor and head track, lined with plasterboard on both faces. Stud metal thickness, Maximum stud spacing on each face, Plasterboard thickness and layers, Finishes, Optional glass wool insulation in the cavity

Details

Category: Framed Walls › Partitions

By Huu Khanh Nguyen · Updated November 14, 2026

Parameters

NameDefaultUnit
Length3000mm
ThicknesstrackDepth + 2 * trackThickness + 2 * boardLayers * boardThicknessmm
Height2700mm
Stud web depthMath.min(Math.max((64), studDocument.options.steelStud.find((row) => row.value == steelStud).depthMin), studDocument.options.steelStud.find((row) => row.value == steelStud).depthMax)mm
Track web depthMath.min(Math.max((92), trackDocument.options.steelTrack.find((row) => row.value == steelTrack).webMin), trackDocument.options.steelTrack.find((row) => row.value == steelTrack).webMax)mm
Stud metal thicknessMath.min(Math.max((0.75), studDocument.options.steelStud.find((row) => row.value == steelStud).thicknessMin), studDocument.options.steelStud.find((row) => row.value == steelStud).thicknessMax)mm
Track metal thicknessMath.min(Math.max((0.5), trackDocument.options.steelTrack.find((row) => row.value == steelTrack).thicknessMin), trackDocument.options.steelTrack.find((row) => row.value == steelTrack).thicknessMax)mm
Maximum stud spacing on one face600mm
Plasterboard thickness13mm
Plasterboard layers per face1
Steel finishceilingGalvanisedSteel
Plasterboard finishceilingPlasterboard
Offset between the two stud facestrackDepth - studDepthmm
Stud baysMath.ceil(2 * sizeX / studSpacing)
Insulationtrue
Insulation ThicknessMath.min(50, studDepth - 16.3)mm
Stud Flange(studThickness == studDocument.options.steelStud.find((row) => row.value == steelStud).thickness ? studDocument.options.steelStud.find((row) => row.value == steelStud).width : studDocument.options.steelStud.find((row) => row.value == steelStud).widthElse)mm